Real Time PCR
Instrument (Exicycler) |
 |
 |
| |
ExicyclerTM96 Quantitative Thermal Block
(hereinafter referred as “Exicycler™ 96”) is the
combination product of thermal cycling block and
Bioneer’s innovative Module of detecting versatile
fluorescences.
It is optimized for measuring gene expression
levels, detecting and quantitating pathogens,
performing allelic discrimination (SNP genotyping)
assays as well as scoring the presence of gene
sequences.
Features
& Benefits:
Exicycler™ 96 is a leading edge system with features
to support labs requiring more capabilities from
their real time PCR platform.
-
Variable excitation and five (5)-color detection
enable you to use a broad range of fluorophores
including FAM™/SYBR® Green I, VIC®/JOE, NED™/
TAMRA™/ Cy3™, ROX™/Texas Red®, and Cy5™ dyes for
greater assay versatility.
-
Measure gene expression levels, detect and
quantitate pathogens, perform allelic
discrimination (SNP genotyping) assays as well as
score the presence of gene sequences.
-
Supports 96-well format plates and 0.2 ml tubes.
-
Powerful, versatile software including plate
set-up wizards and automated analysis tools make
data processing simple and straightforward.
-
ata viewing capabilities and automated analysis
tools.
EXPANSION OF EXICITATION/DETECTION CAPABILITIES:
Exicycler™ 96 is a sophisticated platform for users
who require extended capabilities and maximum
versatility. This features an innovative optical
system that enhances sensitivity and lets you access
a broader range of fluorophores including FAM™/SYBR®
Green I, VIC®/JOE, NED™/ TAMRA™/ Cy3™, ROX™/Texas
Red®, and Cy5™ dyes. The variable excitation
capability allows greater sensitivity for longer
wavelength (red) dyes. This enables to excite and/or
emit up to five pairs of fluorophores for supporting
a wide variety of applications.
|
Filter |
Exi |
Emi |
Dye |
|
1 |
490 |
520 |
FAM, SYBR Green |
|
2 |
520 |
550 |
JOE, VIC, HEX, TET |
|
3 |
550 |
580 |
TAMRA, CY3 |
|
4 |
580 |
610 |
Taxas Red, ROX, RED610 |
|
5 |
640 |
670 |
CY5, RED670 |
FIVE MULTIPLEXING:
Measure changes in gene expression, detect and
quantitate pathogens, and perform allelic
discrimination (SNP genotyping) assays. You can also
confirm the presence or absence of a transgene, or
other specific target sequence. To facilitate some
of these applications, Bioneer provides
preformulated, ready-to-use and quality-tested
TaqMan® assay for use with the Exicycler™ 96. Now
you can reduce your assay optimization efforts. |
 |
 |
|
 |
|
HIGH THROUGHPUT:
Exicycler™ 96 conveys the latest generation Peltier-base
thermal cycling system, which makes you use both
standard 96-well plates and 0.2ml tubes. So, with
Exicycler™ 96, you can process high throughput of
samples in 96-well plates and can detect
fluorescence of 96 samples simultaneously. Also,
sophisticated and versatile platforms for users
requiring extended capabilities feature a unique
optical system that give homogeneity by effectively
minimizing fluorescence differences illuminated on
each well. Therefore, the thermal gradient function
makes uniform and exquisite. Five (5) pairs of
optical configuration support a broader range of
fluorophores. Precision optics and charge-coupled
device (CCD) camera, plus a sophisticated multi-componenting
algorithm is capable superior accuracy,
reproducibility and reliability with no need for
hard ware changes to access new dyes. This feature
enables to be compatible with a robotic instrument
and automatic preparation equipment with Exicycler™
96’s automated door opening capability.
USER
FRIENDLY GUI SOFTWARE:
Exicycler™ 96 features the intuitive graphic use
interface (GUI)-based software offers ease of use
and functionality, including plate set up wizards
guide you through all aspects of experimental set-up
for even complicated multiplex assays, including the
use of multiple standard curves on a single plate.
The real time monitoring feature allows you to watch
PCR amplification as it happens. Data analysis is
simplified with built-in tools such as
auto-baseline, auto-threshold, and SNP auto-calling.
Besides, advance data viewing features allow you to
visualize, report, and understand your data sets. |
|
 |
|
(i)
The Real time monitoring, Auto-baseline and
auto-threshold for simplified data analysis as PCR
amplification happens.
(ii)
Intuitive and flexible Graphic Use Interface
(GUI)-based software. |
|

A linear standard curve from standard samples
ranging 10 to 10 ^8 (or more) in initial
concentration |
|

gene expression levels measure, pathogens detection
& quantitation, the presence of gene sequences
score, and allelic discrimination (SNP genotyping)
assays performance etc. |
|

Minimization of CT value variation within CT 0.5
cycle, even any amplifications are performed at or
around each well. |
|
AFFORDABLE PRICE:
Exicycler™ 96 is a full-featured instrument that
combines high-end results with the most reasonable
price. With Exicycler™ 96, we guarantee the superior
data quality and proven reliability.
Applications:
SNP & Melting Curve Analysis
|
|
SNP
Analysis
Melting Curve Analysis
Technical Specifications |
|
Instrument |
|
Dimension (mm)
|
470(H) x 355(W) x 540(D) |
|
Weight (Kg) |
30 kg |
|
Thermal Cycling
System |
Peltier-based system |
|
Block Format |
96-well block |
|
Compatible
Consumables |
96-well plates and 0.2 mL tubes |
|
Supported Volumes |
20~
50 μL |
|
Operating Temperature |
15-30
℃
|
|
Operating Humidity |
20-80%,
no condensation |
|
Operating System |
Windows
XP |
|
Electrical (Volt/Freq) |
110V
or 220V / 50Hz or 60Hz |
|
External I/O Ports |
USB 2.0 |
|
|
|
|
Thermal Block Specifications |
|
Temperature Range |
4℃
- 99
℃
|
|
Temperature Accuracy |
+/-0.3 |
|
Peak Block Ramp Rate |
Max 2.5
℃/sec
|
|
Gradient Range |
1~ 20
℃
|
|
Gradient Temperature Range |
40~75
℃ |
|
|
|
|
Optical Specifications |
|
Optical System |
UHP short arc lamp (120W)
Five-excitation filters, five-emission filters
and 2D CCD camera |
|
Calibrated Dyes at Installation |
SYBR® Green I, FAM™, JOE™, TAMRA™, ROX™,
Texas Red®, Cy3™, Cy5™ 490~670mm).1℃/s |
|
|
|
|
|
|
|